DCN pre and post sales support

Pre-sales support:
Nte can assist local resellers with the design of DCN systems for smaller conference systems and in particular the stand-alone CCU LBB 3500/05, or can design larger and more complex Congress platforms on a consultant basis. For pre-sales support complete form. >>

The Bosch DCN is extremely flexible but certain rules need to be observed during the design process, including:

The power consumption - The power rating of the contribution units are expressed in terms PCF (Power Consumption Factor) and has a bearing on the number of units that may be connected to the system. >>

System cable limits - There are certain rules regarding the length of the cable that must be taken into consideration. >>

Installation - Nte can assist with the installation, programming and customer training of Congress, or for customers with no DCN training Nte can undertake the complete project. Training on the installation of DCN can also be arranged by Nte. If you require assistance complete the form. >>

After- sales support:
The DCN is supplied with a 3-year manufacturers warranty from Bosch. Nte offer full technical support by telephone or email on all products supplied and is backed-up the the resources of Bosch in the UK, europe and throughout the world.

The Power Consumption Factor (PCF) of contribution units connected to a CCU has a bearing on the total number of such units that can be connected. The maximum number of units quoted for a CCU on this website and in the pdf downloads is based on all units having a PCF of 1. This means that, for example, a stand-alone DCN CCU LBB 3500/05, which can accommodate 90 units of power of PCF can also accommodate 180 units of PCF 0.5.

PCF's for DCN contribution equipment are listed below in the table:

 
Part number Description
PCF
LBB 3510/00 PC Network card - Now 'end-of-line'
1
LBB 3512/00 Data distribution board
1
LBB 3513/00 Analogue audio Input/Output board
1
LBB 3514/00 Trunk splitter
1
LBB 3515/00 Tap-off unit
1
LBB 3520/10 Interpreters unit
2.5
LBB 3524/00 Channel selector panel
0.5
LBB 3524/10 Channel selector panel with backlighting
0.5
LBB 3626/10 Channel selector panel with backlighting (large font)
0.5
LBB 3530/xx Delegate discussion unit
1
LBB 3531xx Delegate discussion unit with channel selector
1
LBB 3533/xx Chairman discussion unit
1
LBB 3534/xx Chairman discussion unit with channel selector
1
LBB 3535/xx Dual audio interface unit
1.5
LBB 3540/xx Multipurpose connection unit with chip card reader
2
LBB 3544/xx Concentus delegate unit
2
LBB 3545/00 Concentus delegate unit with channel selector
2
LBB 3546/00 Concentus unit with graphic LCD and chip-card reader
2.5
LBB 3547/00
2.5
.
The total cable length (using standard LBB 3516/xx) between the CCU and the last unit in any branch of the system must not exceed 250m. This includes all extension cables and the 2m cable that is attached to each system unit.
.
The total length of the extension cable from the CCU to the 1st regenerative tap-off (ie., from Trunk Cable Splitter LBB 3514/00, Audio Media Interface Unit LBB 3508/00 or Extension Power Supply Unit LBB 3506/00) must not exceed 100m.
.
The total length of the extension cable between regenerative tap-off outputs must not exceed 100m.
.
The maximum distance between tabletop units is normally 1.6m with the supplied cable. This distance can be increased by using the LBB 3516/xx Extension Cable Assembly.

Updated 25/7/05